Carstens Medizinelektronik GmbH (1993). Articulograph AG100 User's Handbook. (Göttingen).
Commonwealth of Massachusetts Department of Labor and Industries ( 1986), ``Fixed facilities which generate electromagnetic fields in the frequency range of 300 kilohertz to 100 gigahertz and microwave ovens,'' Code of Massachusetts Regulations 105 CMR 122.000 (Boston, MA).
Federal Republic of Germany (1986). Hazards by electromagnetic fields--protection of persons in the frequency range from 10 kHz to 3000 GHz. VDT 0848 Teil 2 (Deutsche Elektrotechnische Kommission im DIN und VDE).
Foster, K.R. (1995). ``Dielectric properties of tissues,'' in The biomedical engineering handbook, ed. J.D. Bronzino (CRC Press, Boca Raton, FL).
Gauger (1985). ``Household appliance magnetic field survey,'' IEEE Trans. on Power Apparatus and Systems PAS-104(9), 2436-2444.
Haes, D.L. and Fitzgerald, M. (1995). ``Video display terminal very low frequency measurements: The need for protocols in assessing VDT user ``dose'','' Health Physics 68(4), 572-578.
Hoole, P. and Nguyen, N. (1996). ``Electromagnetic articulography in coarticulation research,'' in Instrumental studies of coarticulation, ed. W.J. Hardcastle & N. Hewlett (Camb. Univ. Press, Cambridge).
Institute of Electrical and Electronics Engineers (1992). IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3 kHz to 300 GHz. ANSI Standard C95.1-1991 (IEEE, New York, NY).
International Radiation Protection Association (1988). ``Guidelines on limits of exposure to radiofrequency electromagnetic fields in the frequency range from 100 kHz to 300 GHz,'' Health Physics 54(1), 115-123.
International Radiation Protection Association (1990). ``Interim guidelines on limits of exposure to 50/60 Hz electric and magnetic fields,'' Health Physics 58(1), 113-122.
Kavet, R. and Tell, R.A. (1991). ``VDTs: Field levels, epidemiology, and laboratory studies,'' Health Physics 61(1), 47-57.
Lindbohm, M-L., Hietanen, M., Kyyrönen, P., Sallmén, M., von Nandelstadh, P., Taskinen, H., Pekkarinen, M., Ylikoski, M. and Hemminki, K. (1992). ``Magnetic fields of video display terminals and spontaneous abortion,'' Am. J. of Epidem. 136(9), 1041-1051.
North Atlantic Treaty Organization (1979). ``Control and recording of personnel exposure to radio-frequency radiation.'' Standardization Agreement STANAG No. 2345 (Military Agency for Standardization, Brussels).
Perkell, J.S., Cohen, M., Svirsky, M., Matthies, M., Garabieta, I., and Jackson, M. (1992). ``Electro-magnetic midsagittal articulometer (EMMA) systems for transducing speech articulatory movements,'' J. Acoust. Soc. Am. 92, 3078-3096.
Stuchly, M.A. (1989). ``Canadian and other national RF protection guides,'' in Proceedings of the joint symposium on interaction of electromagnetic waves with biological systems (part of the 22nd General Assembly of the International Union of Radio Science), ed. Lin, C.J. (Plenum Press, New York, NY).
Stuchly, M.A. (1995). ``Low-frequency magnetic fields: Dosimetry, cellular, and animal effects,'' in The biomedical engineering handbook, ed. J.D. Bronzino (CRC Press, Boca Raton, FL).
United States Air Force (1987). ``Occupational health--exposure to radiofrequency radiation.'' AFOSH Standard 161-9 (Washington, D.C.).